4 compounds · Catalog
Ancillaries & Devices
Four consumables decide whether a reconstitution is reproducible: the solvent, the receiving vial, the syringe that measures it, and the filter that sterilises it. None of them is pharmacologically interesting, and all of them are capable of turning a correct peptide into an unusable solution — a non-preserved solvent, a vial with a compromised septum, a syringe that cannot resolve 0.1 mL, or a filter that adsorbs the very peptide it is meant to clarify.
Bacteriostatic water is the default solvent because benzyl alcohol at 0.9 percent suppresses microbial growth in a multi-dose vial. Sterile water without the preservative is the alternative when the peptide tolerates oxidation poorly; the trade-off is a much shorter working life once the vial is punctured.
Compounds in Ancillaries & Devices
Bacteriostatic Water
0.9% benzyl alcohol, sterile USP-grade solvent.
CAS 7732-18-5
Ships in 1–2 days10mL vial · In stock
Sterile Empty Vials
10mL Type-I borosilicate, sterile, ready to use.
10mL vial, flip-off seal
Ships in 1–2 days25 vials/tray · In stock
Insulin Syringes 1mL
29G × 1/2", U-100, individually wrapped.
1mL U-100 syringe
Ships in 1–2 days100 pcs/box · In stock
PTFE Syringe Filters
0.22μm hydrophobic membrane, 25mm.
25mm disc filter
Ships in 1–2 days50 pcs/box · In stock
Devices and their failure modes
Insulin syringes are sold by gauge and barrel volume, and the practical limit is the graduation: a 1 mL barrel marked in 0.01 mL increments resolves ten microlitres, while a 0.3 mL barrel resolves less but caps the volume. PTFE syringe filters are specified by pore size, typically 0.22 micrometre for sterile filtration; PVDF and nylon alternatives adsorb peptides more aggressively, which is why PTFE is the default listed here.
Sterile empty vials are the fourth item, and the one most often substituted without thought. A vial with a butyl rubber septum and an aluminium crimp holds vacuum and survives repeated puncture; a screw-cap vial does neither. Where a batch of vials arrives with a damaged crimp, the septum is no longer a barrier and the contents should not be treated as sterile.
How these are supplied
Solvents and devices ship with the batch documentation appropriate to their class: sterility and endotoxin data for the water, dimensional and material specifications for vials and filters, and needle gauge plus barrel tolerance for syringes. They are consumables, so the certificate is a specification sheet rather than a per-unit analysis, and it is supplied once per lot.
These items are stocked because a peptide order without them tends to be reconstituted with whatever is at hand, which is the most common way a well-documented peptide produces an undocumented result.
Other categories
All compounds in this category are supplied for laboratory research use only — not for human or veterinary application. Certificate of analysis, CAS number and handling data are provided per batch; see quality assurance.